Bottle data collected during the cruise TAlPro2022 (only from CTD sensors)
Repeat hydrography, as organized through the GO-SHIP network, is fundamental for detecting trends and variability also in the Mediterranean Sea. The Mediterranean component of GO-SHIP is MedSHIP, and TAlPro is the western Mediterranean component. The TAlPro2022 cruise consisted of 26 full depth hydrographic stations crossing the Tyrrhenian Sea from north to south, then the Algero-Provencal Basin from south to north. Here the postcalibrated bottle file data are made availiable. Postcalibration has been done by measuring dissolved oxygen and salinity on water samples collected by the rosette.
Identificatie
Versiedatum | 2022-06-08 |
---|---|
Type versiedatum | Creatie: Aanmaakdatum of opnamedatum van de dataset. |
Type versiedatum | Wijziging: Datum van wijziging, controle, verbetering van dataset. |
Versiedatum | 2023-05-11 |
Type versiedatum | Publicatie: Uitgavedatum van de dataset. |
Type versiedatum | Publicatie: Uitgavedatum van de dataset. |
Dataset identificator | 524d7edb-38b8-4a3a-9b2a-dc6f593d98ff |
Inhoud
Contactgegevens dataset(serie)
Organisatie | CNR, Istituto di Scienze Marine (Sezione di Venezia) |
---|---|
Adres | Riva Sette Martiri 1364/A |
Plaats | Venice |
Postcode | 30122 |
Land | Italy |
direttore@ismar.cnr.it | |
Connectiepunt URL | http://www.ismar.cnr.it |
Rol | Originator of Dataset: Originator of Dataset |
Contactgegevens dataset(serie)
Organisatie | Royal Belgian Institute of Natural Sciences, Operational Directorate Natural Environment, Belgian Marine Data Centre |
---|---|
Adres | Vautierstraat 29 |
Plaats | Brussels |
Postcode | 1000 |
Land | Belgium |
bmdc@naturalsciences.be | |
Connectiepunt URL | http://www.bmdc.be |
Rol | Auteur: Partij die auteur is van de data. |
Trefwoorden
GEMET - INSPIRE themes, version 1.0 | Oceanographic geographical features |
---|---|
SeaVoX salt and fresh water body gazetteer | Mediterranean Sea, Western Basin |
SeaDataNet Agreed Parameter Groups |
Dissolved gases
|
SeaDataNet device categories |
CTD
|
SeaVoX Device Catalogue |
Sea-Bird SBE 43 Dissolved Oxygen Sensor
|
SeaDataNet Parameter Discovery Vocabulary |
Electrical conductivity of the water column
|
CRUISE SUMMARY REPORT INVENTORY (CSR) | 120_BSH20223094 |
SeaVoX Platform Categories | research vessel |
EUROPEAN DIRECTORY OF MARINE ENVIRONMENTAL RESEARCH PROJECTS (EDMERP) | EUROFLEETS+: An Alliance of European marine research infrastructure to meet the evolving needs of the research and industrial communities |
MEDIN data format categories | Delimited |
BODC-approved data storage units (Vertical Unit) | Metres |
Taal | English: English |
---|---|
Karakterset | UTF-8: 8-bit variabele grootte universele karakterset, gebaseerd op ISO/IEC 10646 |
Categorie(ën) |
Begrenzing
Omschrijving geografische begrenzing | |
---|---|
Identificator geografische begrenzing |
Begrenzing
Omschrijving geografische begrenzing | |||||||||
---|---|---|---|---|---|---|---|---|---|
Omschrijvende rechthoek
|
|||||||||
Identificator geografische begrenzing |
Referentiesysteem
Horizontaal en/of verticaal referentiesysteem
Naam | WGS 1984 |
---|
Kwaliteit
Niveau kwaliteitsinformatie | Dataset: Informatie heeft betrekking op de dataset. |
---|
Bewerkingen
Algemene beschrijving herkomst | The header of the cnv files created by the SBE PostProcessing Software is pasted below to show the steps of postprocessing. In addition the salinity and dissolved oxygen data have been postcalibrated by using the water samples analysis (salinometer and Winkler titration). The new coefficients that have been applied were: for salinity SLOPE=1.00018712757570; for dissolved oxygen SOC = 0.51092, Voffset = -0.49277, E = 0.0371. HEADER INFORMATION: * Sea-Bird SBE 9 Data File: * FileName = C:\CTD1\2022-12\ctd9.hex * Software Version Seasave V 7.26.7.121 * Temperature SN = 6483 * Conductivity SN = 4940 * Number of Bytes Per Scan = 32 * Number of Voltage Words = 3 * Number of Scans Averaged by the Deck Unit = 1 * System UpLoad Time = May 19 2022 06:41:31 * NMEA Latitude = 41 36.04 N * NMEA Longitude = 010 04.75 E * NMEA UTC (Time) = May 19 2022 06:36:05 * Store Lat/Lon Data = Append to Every Scan * SBE 11plus V 5.2 * number of scans to average = 1 * pressure baud rate = 9600 * NMEA baud rate = 4800 * GPIB address = 1 * advance primary conductivity 0.073 seconds * advance secondary conductivity 0.073 seconds * delete word 3 from scan * delete word 4 from scan * delete word 8 from scan * autorun on power up is disabled * S> ** Ship: Belgica ** Station: CTD9 ** Depth: 663 ** Operator: m * System UTC = May 19 2022 06:41:31 # interval = seconds: 0.0416667 # start_time = May 19 2022 06:41:31 [NMEA time, first data scan] # <Sensors count="9" > # <sensor Channel="1" > # <!-- Frequency 0, Temperature --> # <TemperatureSensor SensorID="55" > # <SerialNumber>6483</SerialNumber> # <CalibrationDate>04-Aug-20</CalibrationDate> # <UseG_J>1</UseG_J> # <A>0.00000000e+000</A> # <B>0.00000000e+000</B> # <C>0.00000000e+000</C> # <D>0.00000000e+000</D> # <F0_Old>0.000</F0_Old> # <G>4.37290371e-003</G> # <H>6.40995572e-004</H> # <I>2.22292592e-005</I> # <J>2.04772567e-006</J> # <F0>1000.000</F0> # <Slope>1.00000000</Slope> # <Offset>0.0000</Offset> # </TemperatureSensor> # </sensor> # <sensor Channel="2" > # <!-- Frequency 1, Conductivity --> # <ConductivitySensor SensorID="3" > # <SerialNumber>4940</SerialNumber> # <CalibrationDate>04-Aug-20</CalibrationDate> # <UseG_J>1</UseG_J> # <!-- Cell const and series R are applicable only for wide range sensors. --> # <SeriesR>0.0000</SeriesR> # <CellConst>2000.0000</CellConst> # <ConductivityType>0</ConductivityType> # <Coefficients equation="0" > # <A>0.00000000e+000</A> # <B>0.00000000e+000</B> # <C>0.00000000e+000</C> # <D>0.00000000e+000</D> # <M>0.0</M> # <CPcor>-9.57000000e-008</CPcor> # </Coefficients> # <Coefficients equation="1" > # <G>-1.00371807e+001</G> # <H>1.45552596e+000</H> # <I>-9.48339360e-004</I> # <J>1.54557934e-004</J> # <CPcor>-9.57000000e-008</CPcor> # <CTcor>3.2500e-006</CTcor> # <!-- WBOTC not applicable unless ConductivityType = 1. --> # <WBOTC>0.00000000e+000</WBOTC> # </Coefficients> # <Slope>1.00018713</Slope> # <Offset>0.00000</Offset> # </ConductivitySensor> # </sensor> # <sensor Channel="3" > # <!-- Frequency 2, Pressure, Digiquartz with TC --> # <PressureSensor SensorID="45" > # <SerialNumber>1432</SerialNumber> # <CalibrationDate>05-May-22</CalibrationDate> # <C1>-4.934648e+004</C1> # <C2>5.421371e-001</C2> # <C3>1.360500e-002</C3> # <D1>3.922500e-002</D1> # <D2>0.000000e+000</D2> # <T1>3.011804e+001</T1> # <T2>-1.330020e-004</T2> # <T3>3.907890e-006</T3> # <T4>2.387590e-009</T4> # <Slope>1.00013520</Slope> # <Offset>-0.40504</Offset> # <T5>0.000000e+000</T5> # <AD590M>1.279770e-002</AD590M> # <AD590B>-9.194870e+000</AD590B> # </PressureSensor> # </sensor> # <sensor Channel="4" > # <!-- A/D voltage 0, Oxygen, SBE 43 --> # <OxygenSensor SensorID="38" > # <SerialNumber>3930</SerialNumber> # <CalibrationDate>04-Sep-20</CalibrationDate> # <Use2007Equation>1</Use2007Equation> # <CalibrationCoefficients equation="0" > # <!-- Coefficients for Owens-Millard equation. --> # <Boc>0.0000</Boc> # <Soc>0.0000e+000</Soc> # <offset>0.0000</offset> # <Pcor>0.00e+000</Pcor> # <Tcor>0.0000</Tcor> # <Tau>0.0</Tau> # </CalibrationCoefficients> # <CalibrationCoefficients equation="1" > # <!-- Coefficients for Sea-Bird equation - SBE calibration in 2007 and later. --> # <Soc>5.1092e-001</Soc> # <offset>-0.4928</offset> # <A>-4.4216e-003</A> # <B> 1.9958e-004</B> # <C>-3.1583e-006</C> # <D0> 2.5826e+000</D0> # <D1> 1.92634e-004</D1> # <D2>-4.64803e-002</D2> # <E> 3.7100e-002</E> # <Tau20> 1.4200</Tau20> # <H1>-3.3000e-002</H1> # <H2> 5.0000e+003</H2> # <H3> 1.4500e+003</H3> # </CalibrationCoefficients> # </OxygenSensor> # </sensor> # <sensor Channel="5" > # <!-- A/D voltage 1, Free --> # </sensor> # <sensor Channel="6" > # <!-- A/D voltage 2, Turbidity Meter, WET Labs, ECO-NTU --> # <TurbidityMeter SensorID="67" > # <SerialNumber>6117</SerialNumber> # <CalibrationDate>JAN-30-2020</CalibrationDate> # <ScaleFactor>25.000000</ScaleFactor> # <!-- Dark output --> # <DarkVoltage>0.023000</DarkVoltage> # </TurbidityMeter> # </sensor> # <sensor Channel="7" > # <!-- A/D voltage 3, Free --> # </sensor> # <sensor Channel="8" > # <!-- A/D voltage 4, Altimeter --> # <AltimeterSensor SensorID="0" > # <SerialNumber>77989</SerialNumber> # <CalibrationDate>2020</CalibrationDate> # <ScaleFactor>15.000</ScaleFactor> # <Offset>0.000</Offset> # </AltimeterSensor> # </sensor> # <sensor Channel="9" > # <!-- A/D voltage 5, Free --> # </sensor> # </Sensors> # datcnv_date = Jun 06 2022 13:32:05, 7.26.7.129 # datcnv_in = C:\TaiPromaggio22\ctd\ctd9.hex C:\TaiPromaggio22\ctd\TaIPRO_postcal_salt_oxy.xmlcon # datcnv_ox_hysteresis_correction = yes # datcnv_ox_tau_correction = yes # datcnv_bottle_scan_range_source = scans marked with bottle confirm bit, 0, 2 # datcnv_scans_per_bottle = 49 # bottlesum_date = Jun 06 2022 13:58:42, 7.26.7.129 # bottlesum_in = C:\TaiPromaggio22\ctd\cnv\ctd9.ros C:\TaiPromaggio22\ctd\TaIPRO_postcal_salt_oxy.xmlcon |
---|
Conformiteit
Domeinconsistentie
Resultaat
|
Domeinconsistentie
Resultaat
|
Domeinconsistentie
Resultaat
|
Toegangs- en gebruiksbeperkingen
Legale en veiligheidsbeperkingen
Beperkingen van de dataset(serie)
|
|||||||||||
Beperkingen van de dataset(serie)
|
Distributie
Overdracht
|
Meta-metadata
Metadata identificator (fileIdentifier) | 524d7edb-38b8-4a3a-9b2a-dc6f593d98ff | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Taal metadatarecord | Engels | ||||||||||||||||
Karakterset metadatarecord | UTF-8: 8-bit variabele grootte universele karakterset, gebaseerd op ISO/IEC 10646 | ||||||||||||||||
Hiërarchisch niveau | Dataset: Informatie heeft betrekking op de dataset. | ||||||||||||||||
Metadata wijzigingsdatum | 2024-10-01T00:00:00 | ||||||||||||||||
Naam metadatastandaard | ISO 19115:2003/19139 | ||||||||||||||||
Versie metadatastandaard | 1.0 | ||||||||||||||||
Metadata-auteur
|