Autonomous temperature probes, data from the EMSO-Azores observatory, 2013-2014
This dataset contains temperature data acquired between August 2013 and July 2014 using 19 temperature probes (HTW, HTNKE and LTW) installed in smoker orifices or cracks. High-temperature WHOI probes (HTW) are composed of 2 J-type thermistors in the rod tip connected to 2 temperature data-loggers (named A & B), 2 data recordings are available for 1 HTW probe. They are able to record temperatures up to 415°C with an accuracy of ± 1.1°C, a resolution of 0.25°C at 375°C and a clock drift of 1min per month. High-temperature NKE probes (HTNKE) are able to record temperatures up to 450°C, with an accuracy of ±0.5°C, a resolution of 0.1°C and a clock drift of 1min/month. Low-temperature WHOI probes (LTW) are able to record temperatures up to 125°C. with an accuracy of ±0.22°C, a resolution of 0.025°C and a clock drift of ±1min per month. The array is not connected to an energy node. All probes are calibrated in time before deployment, probe time adjusted to UTC time. Temperature of probes is checked after recovery and before deployment. Clock drift after recovery is not implemented in data.
owner : {{md.getOwnername()}}
{{'mdStatusRecord' | translate}}: {{('mdStatus-' + md.mdStatus) | translate}}
- Identification
- Content
- ReferenceSystem
- Quality
- DomainConsistancy
- Constraints
- Distribution
- Meta-metadata
- ObjectCatalogue
Date | 2018-09-01 |
---|---|
Date type | Creation: Date identifies when the resource was brought into existence |
Date type | Revision: Date identifies when the resource was examined or re-examined and improved or amended |
Date | 2022-05-23 |
Date type | Publication: Date identifies when the resource was issued |
Date type | Publication: Date identifies when the resource was issued |
Unique resource identifier | 57501b3e-d6e8-470f-ab56-9e143e97263b |
Point of contact
Organisation name | Ifremer, Scientific Information Systems for the sea |
---|---|
Delivery point | IFREMER Centre de Bretagne ZI Pointe du diable CS 10070 |
City | PLOUZANE |
Postal code | 29280 |
Country | France |
Electronic mail address | sismer@ifremer.fr |
Linkage | http://data.ifremer.fr/SISMER |
Role | Dataset Holding Organisation: Dataset Holding Organisation |
Point of contact
Organisation name | Ifremer, Scientific Information Systems for the sea |
---|---|
Delivery point | IFREMER Centre de Bretagne ZI Pointe du diable CS 10070 |
City | PLOUZANE |
Postal code | 29280 |
Country | France |
Electronic mail address | sismer@ifremer.fr |
Linkage | http://data.ifremer.fr/SISMER |
Role | Author: Party who authored the resource |
Descriptive keywords
GEMET - INSPIRE themes, version 1.0 | |
---|---|
SeaVoX salt and fresh water body gazetteer | North Atlantic Ocean |
SeaDataNet Agreed Parameter Groups | Water column temperature and salinity |
SeaDataNet device categories | water temperature sensor |
SeaVoX Device Catalogue | Unknown temperature and pressure sensor |
SeaDataNet Parameter Discovery Vocabulary | Temperature of the water column |
CRUISE SUMMARY REPORT INVENTORY (CSR) |
486_13030040
|
486_14000300
|
SeaVoX Platform Categories | land or seafloor |
MEDIN data format categories | Text or Plaintext |
SeaDataNet Measurement Periodicity Categories | hour to sub-day |
BODC-approved data storage units (Vertical Unit) | Metres |
Language | English: English |
---|---|
Character set | UTF8: 8-bit variable size UCS Transfer Format, based on ISO/IEC 10646 |
Topic category code |
|
Reference System Information
Anchor | WGS 1984 |
---|
Hierarchy level | Dataset: Information applies to the dataset |
---|
Lineage
Statement | This dataset contains temperature data acquired between August 2013 and July 2014 using 19 temperature probes (HTW, HTNKE and LTW) installed in smoker orifices or cracks. High-temperature WHOI probes (HTW) are composed of 2 J-type thermistors in the rod tip connected to 2 temperature data-loggers (named A & B), 2 data recordings are available for 1 HTW probe. They are able to record temperatures up to 415°C with an accuracy of ± 1.1°C, a resolution of 0.25°C at 375°C and a clock drift of 1min per month. High-temperature NKE probes (HTNKE) are able to record temperatures up to 450°C, with an accuracy of ±0.5°C, a resolution of 0.1°C and a clock drift of 1min/month. Low-temperature WHOI probes (LTW) are able to record temperatures up to 125°C. with an accuracy of ±0.22°C, a resolution of 0.025°C and a clock drift of ±1min per month. The array is not connected to an energy node. All probes are calibrated in time before deployment, probe time adjusted to UTC time. Temperature of probes is checked after recovery and before deployment. Clock drift after recovery is not implemented in data. |
---|
Domain consistency
Conformance result
|
Domain consistency
Conformance result
|
Domain consistency
Conformance result
|
mdLegalAndSecurityConstraintsSection
Resource constraints
|
|||||||||||
Resource constraints
|
Transfer options
|
File identifier | 57501b3e-d6e8-470f-ab56-9e143e97263b | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Metadata language | English | ||||||||||||||
Character set | UTF8: 8-bit variable size UCS Transfer Format, based on ISO/IEC 10646 | ||||||||||||||
Hierarchy level | Dataset: Information applies to the dataset | ||||||||||||||
Date stamp | 2024-11-19T00:00:00 | ||||||||||||||
Metadata standard name | ISO 19115:2003/19139 | ||||||||||||||
Metadata standard version | 1.0 | ||||||||||||||
Contact
|
Overviews
extent
- geoDesc
- {{d}}
- geoBox
- geoDescCode
- {{mdView.current.record.geoDescCode}}
tempExtent
- creationDate
- publicationDate
- revisionDate
- tempExtentBegin
Associated resources
Not available